From the Quattro we get a
straight start/stop signal that has to initiate a start sequence
on the generator. Either there will be an AMF panel for the set
in question (that you can get from the generator supplier)
or you can use a generic auto start module that will have to be
configured for the set. Most standby generators are supplied
with or have available a standard auto start module.
This is a remote control and
monitoring panel for the Phoenix Multi/MultiPlus. In
addition, the remote panel also offers PowerControl and
PowerAssist, (simply by setting a maximum AC current with
a 0 to 16A rotary knob), thus preventing the shore supply
or a genset from being overloaded. The brightness of the
LED�s is automatically reduced during night time.
Connection to the Multi is with a standard UTP
cable.
Battery Alarm
An excessively high or low
battery voltage is indicated by an audible and visual
alarm, and a relay for remote signalling.
RJ45 UTP Cable
Allows to connect Phoenix
Inverter Control or VE Interface MK2b.
5M ASS030065000
10M ASS030065010
15M ASS030065020
VE Interface MK.2B
Phoenix Inverters are ready to
communicate with a computer through its RS-485 data port.
All you need to link to your PC in order to be able to set
and read out all parameters is the data link as shown.
Moreover, all Victron Energy products equipped with an
RS-485 data port, such as VE.Net, can easily be integrated
in a computerized monitoring and control system.
Only for models: 12/1200, 12/1600, 12/3000, 12/5000,
24/1200, 24/1600, 24/3000, 24/5000, 48/3000, 48/5000
VE-Configure software and a UTP patch lead required.
Used with RS232 to USB converter and VE Configure
Software.
Two AC inputs with
integrated transfer switch.
The Quattro can be
connected to two independent AC sources, for example
shore-side power and a generator, or two generators. The
Quattro will automatically connect to the active source.