EnergyEnv.co.uk

   
   
    

               OUTBACK CHARGE CONTROLLERS

                Looking for Steca or Morningstar controllers?    Click here


FLEXmax 80A charge controller

The latest Maximum Power Point Tracking (MPPT) charge controller from OutBack Power Systems.

The innovative FLEXmax MPPT software algorithm is both continuous and active, increasing your photovoltaic array power yield up to 30% compared to non-MPPT controllers. Thanks to active cooling and intelligent thermal management cooling, both FLEXmax charge controllers can operate at their full maximum current rating, 60 Amps or 80 Amps respectively, in ambient temperatures as high as 104°F (40°C).

Included in all of the FLEXmax Charge Controllers are the revolutionary features first developed by OutBack Power, including support for a wide range of nominal battery voltages and the ability to step-down a higher voltage solar array to recharge a lower voltage battery bank. A built-in, backlit 80 character display shows the current status and logged system performance data for the last 128 days at the touch of a button. The integrated OutBack network communications allows FLEXmax series Charge Controllers to be remotely programmed and monitored via a MATE system display and provides unrivaled complete system integration

Flexmax 80 CC

Flexmax 80 is £ 665.00 inc VAT

    Delivery is extra at cost

Add Remote Temp Sensor for £35.00

The output current limit of the FLEXmax 80 is 80 amps

Use a minimum of 4 AWG (21.15 mm2) wire for the output between the FLEXmax 80 and the battery bus bar conductors

Install OutBack OBB-80-150VDC-PNL breakers for disconnect and overcurrent protection

The largest PV array that can connect to a Charge Controller must have a rated short-circuit currentof 64 amps or less under STC (Standard Test Conditions).

 

 

FLEXmax 60A charge controller is £ 615.00 inc VAT

    Delivery is extra at cost

   

  • The output current limit of the FLEXmax 60 is 60 amps

  • Use a minimum of 6 AWG (13.3 mm2) wire for the output between the FLEXmax 60 and the battery bus bar conductors

  • Install OutBack OBB-60-150VDC-PNL or OBB-80-150VDC-PNL breakers for disconnect and overcurrent protection

  • The largest PV array that can connect to a Charge Controller must have a rated short-circuit current of 48 amps or less under STC (Standard Test Conditions).

Contact us or call to order 

 

  FLEXmax 80 Specifications FLEXmax 60 Specifications
Nominal Battery Voltages 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up) 12, 24, 36, 48, or 60 VDC (Single model - selectable via field programming at start-up)
Maximum Output Current 80 amps @ 104° F (40°C) with adjustable current limit 60 amps @ 104° F (40°C) with adjustable current limit
Maximum Solar Array STC Nameplate 12 VDC systems 1250 Watts / 24 VDC systems 2500 Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts 12 VDC systems 900 Watts / 24 VDC systems 1800 Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts
NEC Recommended Solar Array STC Nameplate 12 VDC systems 1000 Watts / 24 VDC systems 2000 Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts 12 VDC systems 750 Watts / 24 VDC systems 1500 Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts
PV Open Circuit Voltage (VOC) 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum 150 VDC absolute maximum coldest conditions / 145 VDC start-up and operating maximum
Standby Power Consumption Less than 1 Watt typical Less than 1 Watt typical
Power Conversion Efficiency 97.5% @ 80 Amps in a 48 VDC System - Typical 98.1% @ 60 Amps in at 48 VDC System voltage - Typical
Charging Regulation Five Stages: Bulk, Absorption, Float, Silent and Equalization Five Stages: Bulk, Absorption, Float, Silent and Equalization
Voltage Regulation Set points 10 to 80 VDC user adjustable with password protection 10 to 60 VDC user adjustable with password protection
Equalization Charging Programmable Voltage Setpoint and Duration - Automatic Termination when completed Programmable Voltage Setpoint and Duration - Automatic Termination when completed
Battery Temperature Compensation Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell Automatic with optional RTS installed / 5.0 mV per °C per 2V battery cell
Voltage Step-Down Capability Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input Can charge a lower voltage battery from a higher voltage PV array - Max 150 VDC input
Programmable Auxilary Control Output 12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
12 VDC output signal which can be programmed for different control applications
(Maximum of 0.2 amps DC)
Status Display 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total 3.1" (8 cm) backlit LCD screen - 4 lines with 80 alphanumeric characters total
Remote Display and Controller Optional Mate or Mate2 with RS232 Serial Communications Port Optional Mate or Mate2 with RS232 Serial Communications Port
Network Cabeling Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires) Proprietary network system using RJ 45 Modular Connectors with CAT 5e Cable (8 wires)
Data Logging Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production Last 128 days of Operation - Amp Hours, Watt Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage, Max Battery Voltage Min Battery Voltage and Absorb for each day along with total Accumulated Amp Hours, and kW Hours of production
Hydro Turbine Applications Consult factory for approved Turbines Consult factory for approved Turbines
Positive Ground Applications Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications) Requires two Pole Breakers for switching both positive and Negative Conductors on both Solar Array and Battery Connections (HUB-4 and HUB-10 can not be used for use in positive ground applications)
Operating Temperature Range Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when operated above 40° C)
Environmental Rating Indoor Type 1 Indoor Type 1
Conduit Knockouts One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom One 1" (35mm)on the back; One 1" (35mm) on the left side; Two 1" (35mm) on the bottom
Warranty Standard 5 year / Available 10 Year Standard 5 year / Available 10 Year
Weight - Unit 12.20 lbs (5.56 kg) 11.65 lbs (5.3 kg)
            - Shipping 15.75 lbs (7.10 kg) 14.55 lbs (6.4 kg)
Dimensions - Unit 16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D)
13.5 x 5.75 x 4" (40 x 14 x 10 cm)
                   - Shipping 21" x 10.5" x 9.75" (53 x 27 x 25 cm) 18 x 11 x 8" (46 x 30 x 20 cm)
Options Remote Temperature Sensor (RTS), HUB 4,HUB 10, MATE, MATE 2 Remote Temperature Sensor (RTS), HUB 4,HUB 10, MATE, MATE 2

 


Contact us or call to order 

                 

 

 

 

Secure online payments with WorldPay

         

 Energy & Environment is an Ethical Junction member

LINKS in Orange

WIND POWER          

RenewableUK                                              

Small Wind   

SOLAR POWER           

Solar Power Portal                                                          

Case Studies

The Solar Guide 

PV REGULATORS     

           

INVERTERS  Grid      

            

INVERTERS  Off Grid     

      

INVERTER COMBIS     

                                                    

MARINE SOLAR 

                     

WIND TURBINES

Small < 1 Kw

VAWTs  to 100Kw        

                                                     

SOLAR LIGHTING

Streetlights

Road Studs

Warning Lights

Solarbricks

 

AD / BIOGAS


 

 

NEWS

Supply of 50KWp of PV trackers to project in the East Midlands.

Supply of PV trackers to projects in The West Midlands & Kent.

Supply of complete off grid solar system to Univ. of West of Scotland.        

Supply of 20KW of solar PV to single project in Sudan.

Supply of complete 2KW wind turbine system + 5000W inverter  in Kent

Supply & installation of complete off-grid 2KW wind turbine + diesel genset and batteries near Doncaster.

Supply & installation of PV system for battery charging in Manchester.