FLEXmax 80 Specifications |
FLEXmax 60 Specifications |
| Nominal Battery Voltages |
12, 24, 36, 48, or 60 VDC (Single model -
selectable via field programming at start-up) |
12, 24, 36, 48, or 60 VDC (Single model -
selectable via field programming at start-up) |
| Maximum Output Current |
80 amps @ 104° F (40°C) with adjustable current
limit |
60 amps @ 104° F (40°C) with adjustable current
limit |
| Maximum Solar Array STC Nameplate |
12 VDC systems 1250 Watts / 24 VDC systems 2500
Watts / 48 VDC systems 5000 Watts / 60 VDC systems 6250 Watts |
12 VDC systems 900 Watts / 24 VDC systems 1800
Watts / 48 VDC systems 3600 Watts / 60 VDC Systems 4500 Watts |
| NEC Recommended Solar Array STC
Nameplate |
12 VDC systems 1000 Watts / 24 VDC systems 2000
Watts / 48 VDC systems 4000 Watts / 60 VDC Systems 5000 Watts |
12 VDC systems 750 Watts / 24 VDC systems 1500
Watts / 48 VDC systems 3000 Watts / 60 VDC Systems 3750 Watts |
| PV Open Circuit Voltage (VOC) |
150 VDC absolute maximum coldest conditions /
145 VDC start-up and operating maximum |
150 VDC absolute maximum coldest conditions /
145 VDC start-up and operating maximum |
| Standby Power Consumption |
Less than 1 Watt typical |
Less than 1 Watt typical |
| Power Conversion Efficiency |
97.5% @ 80 Amps in a 48 VDC System - Typical |
98.1% @ 60 Amps in at 48 VDC System voltage -
Typical |
| Charging Regulation |
Five Stages: Bulk, Absorption, Float, Silent and
Equalization |
Five Stages: Bulk, Absorption, Float, Silent and
Equalization |
| Voltage Regulation Set points |
10 to 80 VDC user adjustable with password
protection |
10 to 60 VDC user adjustable with password
protection |
| Equalization Charging |
Programmable Voltage Setpoint and Duration -
Automatic Termination when completed |
Programmable Voltage Setpoint and Duration -
Automatic Termination when completed |
| Battery Temperature Compensation |
Automatic with optional RTS installed / 5.0 mV
per °C per 2V battery cell |
Automatic with optional RTS installed / 5.0 mV
per °C per 2V battery cell |
| Voltage Step-Down Capability |
Can charge a lower voltage battery from a higher
voltage PV array - Max 150 VDC input |
Can charge a lower voltage battery from a higher
voltage PV array - Max 150 VDC input |
| Programmable Auxilary Control
Output |
12 VDC output signal which can be programmed
for different control applications
(Maximum of 0.2 amps DC) |
12 VDC output signal which can be programmed
for different control applications
(Maximum of 0.2 amps DC) |
| Status Display |
3.1" (8 cm) backlit LCD screen - 4 lines with
80 alphanumeric characters total |
3.1" (8 cm) backlit LCD screen - 4 lines with
80 alphanumeric characters total |
| Remote Display and Controller |
Optional Mate or Mate2 with RS232 Serial
Communications Port |
Optional Mate or Mate2 with RS232 Serial
Communications Port |
| Network Cabeling |
Proprietary network system using RJ 45 Modular
Connectors with CAT 5e Cable (8 wires) |
Proprietary network system using RJ 45 Modular
Connectors with CAT 5e Cable (8 wires) |
| Data Logging |
Last 128 days of Operation - Amp Hours, Watt
Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage,
Max Battery Voltage Min Battery Voltage and Absorb for each day
along with total Accumulated Amp Hours, and kW Hours of
production |
Last 128 days of Operation - Amp Hours, Watt
Hours, Time in Float , Peak Watts, Amps, Solar Array Voltage,
Max Battery Voltage Min Battery Voltage and Absorb for each day
along with total Accumulated Amp Hours, and kW Hours of
production |
| Hydro Turbine Applications |
Consult factory for approved Turbines |
Consult factory for approved Turbines |
| Positive Ground Applications |
Requires two Pole Breakers for switching both
positive and Negative Conductors on both Solar Array and Battery
Connections (HUB-4 and HUB-10 can not be used for use in
positive ground applications) |
Requires two Pole Breakers for switching both
positive and Negative Conductors on both Solar Array and Battery
Connections (HUB-4 and HUB-10 can not be used for use in
positive ground applications) |
| Operating Temperature Range |
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when
operated above 40° C) |
Minimum -40° to maximum 60° C
(Power capacity of the controller is automatically derated when
operated above 40° C) |
| Environmental Rating |
Indoor Type 1 |
Indoor Type 1 |
| Conduit Knockouts |
One 1" (35mm)on the back; One 1" (35mm) on the
left side; Two 1" (35mm) on the bottom |
One 1" (35mm)on the back; One 1" (35mm) on the
left side; Two 1" (35mm) on the bottom |
| Warranty |
Standard 5 year / Available 10 Year |
Standard 5 year / Available 10 Year |
| Weight
- Unit |
12.20 lbs (5.56 kg) |
11.65 lbs (5.3 kg) |
|
- Shipping |
15.75 lbs (7.10 kg) |
14.55 lbs (6.4 kg) |
| Dimensions
- Unit |
16.25" x 5.75" x 4" (41.3 x 14 x 10 cm) -
(H x W x D) |
13.5 x 5.75 x 4" (40 x 14 x 10 cm) |
|
- Shipping |
21" x 10.5" x 9.75" (53 x 27 x 25 cm) |
18 x 11 x 8" (46 x 30 x 20 cm) |
| Options |
Remote Temperature Sensor (RTS), HUB 4,HUB 10,
MATE, MATE 2 |
Remote Temperature Sensor (RTS), HUB 4,HUB 10,
MATE, MATE 2 |