SUNMASTER GRID CONNECT INVERTERS
For the Soladin 600 mini grid tie inverters
click here Mastervolt supply a broad range of solar
inverters as a vital part of solar power systems, equally at
home or for autonomous applications. Please use the
PV system design
calculator Excel for your
convenience
.
FULLY G83 CERTIFIED FOR UK USE.
The Mastervolt Sunmaster inverter is the
dynamic heart of any grid connected PV system, taking care of an
accurate power conversion from PV array to local grid. This
conversion process takes place with minimal power loss and
maximum reliability. F
Added value comes from the extensive
monitoring function, which is integrated within the design of
the QS inverters.
|
|
SUNMASTER
MODELS Model
QS = The Sunmaster QS is the dynamic
heart of any grid-connected photovoltaic (PV) system, taking care
of an accurate power conversion from solar panel to local grid.
This effective conversion process takes place with minimal power
loss and maximum reliability. All Sunmaster QS solar inverters can
be installed to operate in parallel, which enables configuration
of grid-connected PV systems of unlimited power rating. Thanks to
the QS inverters, PV systems can be assembled from 600 Wp to high
kWp specifications. Added value comes from the extensive
monitoring function, which is integrated within the design of the
QS inverters, and control programme. These options, varying from
display and software to data storage and internet readout, allows
you to retrieve all the data you want from your PV system. Through
the application of the latest high frequency (HF) technology, the
transformers of the Sunmaster QS inverters are very small. The
result is an extremely compact and light weight power conversion
design, layed out on one single power board.
The Sunmaster operates completely silently:
temperature-controlled, maintenance-free ventilators take care of
the cooling of the power electronics. In addition to the fabulous
accurate regulation of all inverter parameters, the control
electronics measures and monitors the most relevant PV array,
inverter and grid functions. All Sunmaster inverters are fitted in
a robust aluminium enclosure for indoor installation (IP23). |
|
|
|
Sunmaster
IP44 series UK version
With the new Sunmaster
IP44 series efficiency and optimum power output are guaranteed,
even in the most arduous of locations. The IP44 waterproof
enclosure allows for installation in most protected outdoor areas.
Once connected to the PV modules in your system, the low weight
inverter delivers the power! Our world proven HP transformer
technology is as ever built in to a compact housing, making
installation simple and quick. Integrated heavy duty DC load
switching adds to greater safety and simplicity in use – this
comes standard on all ENS versions. Mastervolt is proud to offer
you yet another innovative product with the introduction of a new
and advanced LCD display with miniature data logger - storage of
data for up to 30 days - giving you the profitable facts.
For Technical specs for
the whole Sunmaster range.....
click here
Sunmaster
QS2000 IP44 UK Version
Part numbers
130802000 (130812000

|
Typical string length |
5-9 modules (72
cells), 7-12 modules (54 cells) or 10-18 modules (36 cells).
Max-I model: 4-6 modules (72 cells), 6-9 modules (54 cells) or
8-12 modules (36 cells) |
| SOLAR INPUT |
|
| Nominal power 40 °C amb. temp. |
1700 W DC |
| PV power range |
1200-2100 Wp |
| Maximum input |
1800 W |
| MPP tracker |
I MPP tracker |
| MPP voltage range |
100-380 V DC |
| Maximum voltage |
450 V DC |
| Nominal rated current |
7.5 A |
| GRID OUTPUT INVERTERS |
|
| Voltage |
230 V AC (184-265 V, depending on
model/setting), single phase |
| Nominal output |
1600 W |
| Maximum output |
1725 W |
| Nominal current |
7.0 A |
| Frequency |
50 Hz (48-52 Hz, depending on
model/setting) |
| Power factor |
0.99 |
| Harmonic distortion (THD) |
3% rated load, in compliance with IEEE |
| Standby power |
0 W |
| European efficiency |
94 % |
| Maximum efficiency |
95 % |
CALL or email
for PRICES
|
|
Sunmaster QS3500 IP44
UK Version
Part numbers
130803500 (130813500)

|
Typical string length |
5-9 modules (72 cells),
7-12 modules (54 cells) or 10-18 modules (36 cells). Max-I
model: 4-6 modules (72 cells), 6-9 modules (54 cells) or 8-12
modules (36 cells) |
| SOLAR INPUT |
|
| Nominal power 40 °C amb. temp. |
2750 W DC |
| PV power range |
2000-3600 Wp |
| Maximum input |
2950 W |
| MPP tracker |
2 MPP tracker |
| MPP voltage range |
100-380 V DC |
| Maximum voltage |
450 V DC |
| Nominal rated current |
2 x 7.5 A or 1 x 15 A |
| GRID OUTPUT INVERTERS |
|
| Voltage |
230 V AC (184-265 V, depending on
model/setting), single phase |
| Nominal output |
2600 W |
| Maximum output |
2750 W |
| Nominal current |
12.0 A |
| Frequency |
50 Hz (48-52 Hz, depending on
model/setting) |
| Power factor |
0.99 |
| Harmonic distortion (THD) |
3% rated load, in compliance with IEEE |
| Standby power |
0 W |
| European efficiency |
94 % |
| Maximum efficiency |
95 % |
CALL or email
for PRICES
|
|
Sunmaster QS3500
Max-I
IP44
UK Version
Part numbers
130903500 (130913500

|
Typical string length |
5-9 modules (72 cells),
7-12 modules (54 cells) or 10-18 modules (36 cells). Max-I
model: 4-6 modules (72 cells), 6-9 modules (54 cells) or 8-12
modules (36 cells) |
| SOLAR INPUT |
|
| Nominal power 40 °C amb. temp. |
2750 W DC |
| PV power range |
2000-3600 Wp |
| Maximum input |
2950 W |
| MPP tracker |
2 MPP tracker |
| MPP voltage range |
75-260 V DC |
| Maximum voltage |
325 V DC |
| Nominal rated current |
2 x 10 A or 1 x 20 A |
| GRID OUTPUT INVERTERS |
|
| Voltage |
230 V AC (184-265 V, depending on
model/setting), single phase |
| Nominal output |
2600 W |
| Maximum output |
2750 W |
| Nominal current |
12.0 A |
| Frequency |
50 Hz (48-52 Hz, depending on
model/setting) |
| Power factor |
0.99 |
| Harmonic distortion (THD) |
3% rated load, in compliance with IEEE |
| Standby power |
0 W |
| European efficiency |
94.5 % |
| Maximum efficiency |
95 % |
CALL or email
for PRICES
Sunmaster
XS6500
IP44
UK Version
Part numbers
131006500 (131016500

-
Can be installed outside with minor
environmental protection
-
100% output, even at high ambient
temperatures
-
DC Switch and extended LCD monitor
supplies as standard
-
extremely efficient: high yield
|
Typical string length |
12-25 modules (35 cells),
7-17 modules (54 cells) or 6-12 modules (72 cells) |
| Relative humidity |
95% max. - PCB has anti-moisture coating |
| Protection degree |
IP44 |
| Safety degree |
Class I |
| Galvanic isolation |
Class II |
|
GRID OUTPUT INVERTERS |
| Nominal current |
22.0 A |
| Harmonic distortion (THD) |
3% rated load, in compliance with IEEE |
| Dimensions (HxWxD) |
725 x 356 x 145 mm |
| Operating temperature |
-20 °C to 50 °C, protected against
overtemperature |
| Storage temperature |
-20 °C to 70 °C |
| Weight |
15 kg |
| Nominal power 40 °C amb. temp. |
5325 W DC |
| Maximum
input |
5600 W |
| Start-up power |
10 W |
| Voltage |
230 V AC (184-265 V, depending on
model/setting), single phase |
| Frequency |
50 hz (48-52 Hz, depending on model/setting) |
| Power factor |
0.99 |
| Standby power |
< 0.5 W |
| AC connection |
PG 13.5 gland & screw terminals 2.5-4 mm² |
| Nominal output |
5000 W (In Germany 4600 W, single phase) |
| Maximum output |
5200 W (In Germany 4600 W, single phase) |
| Maximum efficiency |
95 % |
| European efficiency |
94 % |
CALL or email
for PRICES
|
|
Monitoring for SUNMASTER solar inverters
Every grid-connected solar system needs
photovoltaic modules /solar panels and a solar
inverter to power your home or company.
Data Control Basic (standard for the Sunmaster range)
Every Sunmaster model comes as standard with an integrated
RS485 communication interface and a ten-day power output memory. This
makes the entire PV system interactive, with the option of reading the
most essential information using your PC or laptop. All that is
required to connect the Sunmaster with your computer is a
communication cable and PC link (adapter plug). The software for
reading out the data under Microsoft Windows is available free of
charge in the Download & Support section of this website.
Data monitoring: Data Control
Premium II
As a follow-up to the successful ‘Premium’ model for mediumsized
systems, the new Premium II offers numerous new functions and an
extended operating range. Based on the Data Control Professional
concept, it provides a functional scope previously only found in
extremely large systems. Professional quality at a reasonable price: a
unique offer! Two Premium II versions are available for different
fields of applications
. Premium II Local
With incorporated Ethernet (network) interface. Applications:
- Data transmission to PC/port, directly or via network/evaluation
via Premium II PC software.
- Data transmission via internet with the existing ADSL
connection/evaluation via the Mastervolt portal.
2. Premium II Remote
With integrated analogue modem. Applications:
- Remote data transmission to PC, evaluation via Premium II PC
software.
- Remote data transmission via the Mastervolt server, evaluation
via the Mastervolt portal.
Data registration
A QS data interface connects all inverters with the Premium
II data registration unit. Up to six inverters can be connected. The
Premium II data logger continuously communicates with all connected
inverters and saves all current measured values and system data every
10 minutes. The device offers a large data memory for values measured
over a period of up to three years (depending on the configuration).
Internet data monitoring: Data Control
Pro
The Data Control Professional data logger provides
monitoring, read outs and alarm warnings via the internet. During the
day, the data logger extracts information on power output directly
from up to 20 Sunmaster inverters via the QS data port. This
eliminates the need for external kWh meters. Overnight, the collected
data is sent to a web page, from which it can later be accessed from
anywhere in the world using a log in code. Exceptionally accurate
weather prediction data is used to assess the output of the PV system.
An important advantage of the system is the link from the local
monitoring to the weather registration of Meteomedia in Germany. An
external reference cell is not required.
Should the Sunmaster inverters report a system
fault or the solar yield not conform to the expected specified value,
an alarm routine of the Safer Sun Programme is activated. According to
the settings, an alarm is triggered on site at the device itself or a
warning message is sent by email, fax or SMS. This superior monitoring
method ensures a high availability of the recording device, which in
turn enables a large number of systems to be monitored.
|
Call : 0161 881 1383 to order
|
| |
|
 |


|
NEWS
March 2008
Completion of WES
Tulipo installations near Coventry and in Blackburn.
----------------
Completion of
off-grid power system near Doncaster.
OFFERS
Best prices NOW on
complete solar PV and Solar thermal systems.
|

|
 |