for AGM Batteries 55Ah, 70Ah, 90Ah, 130Ah, 160Ah, 225Ah, 270Ah

AGM 12/55

Battery AGM 12V/55 Ah

Part 62000550

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 55 Ah
Dimensions excluding poles (LxWxH) 257 x 132 x 200 mm/10.1 x 5.2 x 7.9 inch
Dimensions including poles (LxWxH) 257 x 132 x 207 mm/10.1 x 5.2 x 8.2 inch
Weight 17 kg/37.5 lbs
Maximal installation angle 180°
Cold starter current DIN 492A
Cold starter current SAE 562A
Short circuit current (IEC 60896-21) 1500A

AGM 12/70

Battery AGM 12V/70 Ah

Part 62000700

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 70 Ah
Dimensions excluding poles (LxWxH) 348 x 167 x 178 mm/13.7 x 6.6 x 7 inch
Dimensions including poles (LxWxH) 348 x 167 x 181 mm/13.7 x 6.6 x 7.1 inch
Weight 22.2 kg/49 lbs
Maximal installation angle 180°
Cold starter current DIN 617A
Cold starter current SAE 705A
Short circuit current (IEC 60896-21) 1620A

AGM 12/90

Battery AGM 12V/90 Ah

Part 62000900

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 90 Ah
Dimensions excluding poles (LxWxH) 330 x 173 x 212 mm/13 x 6.8 x 8.3 inch
Dimensions including poles (LxWxH) 330 x 173 x 237 mm/13 x 6.8 x 9.3 inch
Weight 30 kg/66 lbs
Maximal installation angle 180°
Cold starter current DIN 885A
Cold starter current SAE 1012A
Short circuit current (IEC 60896-21) 2000A

AGM 12/130

Battery AGM 12V/130 Ah

Part 62001300

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 130 Ah
Dimensions excluding poles (LxWxH) 410 x 177 x 225 mm/16.1 x 7 x 8.9 inch
Dimensions including poles (LxWxH) 410 x 177 x 228 mm/16.1 x 7 x 9 inch
Weight 37 kg/83 lbs
Maximal installation angle 180°
Cold starter current DIN 1249A
Cold starter current SAE 1425A
Short circuit current (IEC 60896-21) 2000A

AGM 12/160

Battery AGM 12V/160 Ah

Part 62001600

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 160 Ah
Dimensions excluding poles (LxWxH) 485 x 170 x 242 mm/19.1 x 6.7 x 9.5 inch
Dimensions including poles (LxWxH) 485 x 170 x 242 mm/19.1 x 6.7 x 9.5 inch
Weight 43 kg/95 lbs
Maximal installation angle 180°
Cold starter current DIN 1518A
Cold starter current SAE 1722A
Short circuit current (IEC 60896-21) 3500A

AGM 12/225

Battery AGM 12V/225 Ah

Part 62002250

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 225 Ah
Dimensions excluding poles (LxWxH) 522 x 240 x 218 mm/20.6 x 9.4 x 8.6 inch
Dimensions including poles (LxWxH) 522 x 240 x 241 mm/20.6 x 9.4 x 9.5 inch
Weight 64 kg/141 lbs
Maximal installation angle 180°
Cold starter current DIN 1980A
Cold starter current SAE 2261A
Short circuit current (IEC 60896-21) 3650A

AGM 12/270

Battery AGM 12V/270 Ah

Part 62002700

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 270 Ah
Dimensions excluding poles (LxWxH) 522 x 268 x 220 mm/20.6 x 10.6 x 8.7 inch
Dimensions including poles (LxWxH) 522 x 268 x 243 mm/20.6 x 10.6 x 9.6 inch
Weight 73 kg/161 lbs
Maximal installation angle 180°
Cold starter current DIN 2239A
Cold starter current SAE 2557A
Short circuit current (IEC 60896-21) 4400A

 

Contact us


Batteries 12V MVG (Gel)

2 year warranty

Gel batteries are very suitable as service batteries due to the fact that they can be quickly charged and have a long lifespan, even with many charge/discharge cycles.

Contact us

--------------------------------------------------------------------------------------------


Datasheets
for GEL Batteries 12/25, 12/55, 12/85, 12/120, 12/140, 12/200

MVG 12/25 (gel)

Battery MVG (gel) 12V/25 Ah

Part 64000250

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 25 Ah
Dimensions excluding poles (LxWxH) 164 x 173 x 126 mm /6.46 x 6.81 x 4.96 inch
Dimensions including poles (LxWxH) 167 x 176 x 126 mm/6.57 x 6.93 x 4.96 inch
Weight 9.6 kg/21.2 lbs
Maximal installation angle 180°
Cold starter current DIN 110A
Cold starter current SAE 175A
Start in kW (diesel) 30
Start in kW (petrol) 38
Short circuit current (IEC 60896-21) 583A

MVG 12/55 (gel)

Battery MVG (gel) 12V/55 Ah

Part 64000550

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 55 Ah
Dimensions excluding poles (LxWxH) 253 x 133 x 208 mm /9.96 x 5.24 x 8.19 inch
Dimensions including poles (LxWxH) 261 x 136 x 230 mm /10.28 x 5.35 x 9.09 inch
Weight 19 kg/41.9 lbs
Maximal installation angle 180°
Cold starter current DIN 230A
Cold starter current SAE 380A
Start in kW (diesel) 50
Start in kW (petrol) 65
Short circuit current (IEC 60896-21) 1403A

MVG 12/85 (gel)

Battery MVG (gel) 12V/85 Ah

Part 64000850

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 85 Ah
Dimensions excluding poles (LxWxH) 330 x 171 x 214 mm/12.99 x 6.73 x 8.43 inch
Dimensions including poles (LxWxH) 330 x 171 x 236 mm/12.99 x 9.73 x 9.29 inch
Weight 32.6 kg/71.9 lbs
Maximal installation angle 180°
Cold starter current DIN 270A
Cold starter current SAE 450A
Start in kW (diesel) 70
Start in kW (petrol) 90
Short circuit current (IEC 60896-21) 2018A

MVG 12/120 (gel)

Battery MVG (gel) 12V/120 Ah

Part 64001200

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 120 Ah
Dimensions excluding poles (LxWxH) 475 x 178 x 195 mm/18.70 x 7.01 x 7.68 inch
Dimensions including poles (LxWxH) 513 x 189 x 223 mm/20.20 x 7.44 x 8.78 inch
Weight 41 kg/90.4 lbs
Maximal installation angle 180°
Cold starter current DIN 450A
Cold starter current SAE 760A
Start in kW (diesel) 130
Start in kW (petrol) 155
Short circuit current (IEC 60896-21) 2475A

MVG 12/140 (gel)

Battery MVG (gel) 12V/140 Ah 

Part 64001400

Ah capacity/C20 (capacity at 20 hours of discharge time at a surrounding temperature of 25°C) 140 Ah
Dimensions excluding poles (LxWxH) 475 x 210 x 195 mm/18.70 x 8.27 x 7.68 inch
Dimensions including poles (LxWxH) 513 x 223 x 223 mm/20.20 x 8.78 x 8.78 inch
Weight 49 kg/108 lbs
Maximal installation angle 180°
Cold starter current DIN 540A
Cold starter current SAE 920A
Start in kW (diesel) 160
Start in kW (petrol) 190
Short circuit current (IEC 60896-21) 3132A

MVG 12/200 (gel)

Battery MVG (gel) 12V/200 Ah

Part 64002000

discharge time at a surrounding temperature of 25°C) 200 Ah
Dimensions excluding poles (LxWxH) 475 x 265 x 216 mm/18.70 x 10.43 x 8.50 inch
Dimensions including poles (LxWxH) 518 x 274 x 238 mm/20.39 x 10.79 x 9.37 inch
Weight 70 kg/154.3 lbs
Installation length 180°
Cold starter current DIN 630A
Cold starter current SAE 1100A
Start in kW (diesel) 175
Start in kW (petrol) 220
Short circuit current (IEC 60896-21) 3606A

 

                                                  

 Pallet cost for UK mainland delivery is £45.00 inc VAT

Contact us

for information or to order

 

 

 


GEL BATTERIES GENERAL INFORMATION

A battery is made up of several cells, which produce electricity through a chemical-electrical process. Electricity is generated by the conversion of lead and lead oxide into lead sulphate in a battery box filled with a water/acid solution. This process is called discharging the battery. For recharging, the battery’s minus and plus terminals are connected to a battery charger, an alternator, a solar panel, etc. (i.e. a direct current source). This causes a chemical reaction, which converts the lead sulphate back into lead and lead oxide. When the battery is fully recharged, an explosive mixture called oxyhydrogen is formed. An open flame or sparks in the vicinity can therefore be extremely hazardous. With Mastervolt’s gel batteries you can eliminate this danger.


A gel battery is a ‘normal’ lead sulphuric acid battery available in the so-called semi-traction (12 Volt) and traction versions (2 Volt cells). The main difference between a gel battery and the traditional ‘wet’ battery (whether open or sealed) is a gel substance which holds the electrolyte mix. The gases that are produced during the charging process are converted to liquid within the gel battery. This so-called recombination process prevents any gases from escaping and is what makes the gel battery so suitable for use as a service battery.

The charge voltage is given at a surrounding temperature of 20ºC. Mastervolt’s charging equipment with temperature sensor follows the correct temperature curve:

• Absorption stage = 14.4/28.8V DC at 20ºC, 14.2/28.5V at 25ºC.

• Float stage = 13.8/27.6V DC at 20ºC, 13.2/26.5V at 25ºC.

If there is no 3-stage charging equipment available, the voltage must be adjusted to a level of under 14 or 28V at 20ºC.

 


There are three main categories of batteries: starter, service and 2 Volt. Each can be subdivided into low-maintenance, maintenance-free and ‘normal’ rechargeable batteries.


These batteries are designed to generate a large amount of Amperes in a short burst of 5 to 15 seconds. Once the engine of the vehicle or vessel is running, the battery is recharged by the alternator. Mastervolt recommends installing a modern semi-traction battery instead, as these are designed for starting as well as for regular energy generation. Be careful when buying a battery: maintenance-free starter batteries are often sold as maintenance-free service batteries, boasting a high amount of charge/ discharge cycles with an extremely slow discharge over a long period of time.


These batteries are intended for long-term use, in particular for regular power consumption with a discharge time span of 5 to 24 hours. This type of battery is available in open or sealed gel versions and has a life expectancy of 5 to 6 years. Expressed in cycles, the battery’s life-span is about 400 charge/ discharge cycles (in a 50% discharged state).


These have a life-span of 10 to 20 years. This heavy-duty traction version can cope with an intensive, long term state of discharge. Complete expiry of the battery shortens the traction battery’s life-span less than it does with the semi-traction versions. For daily intensive use we recommend a traction gel battery with a suitable three-stage charge system.

 

picture


A gel battery requires less engine or generator running time to recharge. In a power system with an integrated inverter or Combi, it is desirable that the energy used up is recharged in a short period of time. A gel battery is constructed in such a way that it can recharge with a charge current equal to 50% of the Ah capacity. A 12V/200 Ah gel battery can therefore be charged with 100A, for example, according to the 3-stage charge characteristic recommended by Mastervolt. This reduces charging time to a minimum.


pictureNo more worrying about high temperatures in summer and low temperatures in winter, or topping up with distilled water: a gel battery does not require any maintenance whatsoever. The only proviso is that you use a good battery charger


pictureAs gel batteries discharge virtually none of their energy, there is no need to keep topping up with a battery charger. The battery will still be fully charged after half a year, although it is of course always better to have your battery permanently connected to a battery charger or solar panel.


pictureSafety comes first, and gel batteries are definitely your safest option. The so-called low-maintenance batteries release gas while recharging. These heavy electrolyte fumes can remain suspended in the air, and if they come into contact with a spark or open flame can even explode. Gel batteries, on the other hand, release virtually no gas. Neither do they leak acid when damaged or held at an angle, as the electrolyte is retained in the gel substance.

 

 

 

   

Secure online payments with WorldPay

         

 Energy & Environment is an Ethical Junction member

LINKS in Orange

WIND POWER          

RenewableUK                                              

Small Wind   

SOLAR POWER           

Solar Power Portal                                                          

Case Studies

The Solar Guide 

PV REGULATORS     

           

INVERTERS  Grid      

            

INVERTERS  Off Grid     

      

INVERTER COMBIS     

                                                    

MARINE SOLAR 

                     

WIND TURBINES

Small < 1 Kw

VAWTs  to 100Kw        

                                                     

SOLAR LIGHTING

Streetlights

Road Studs

Warning Lights

Solarbricks

 

AD / BIOGAS


 

 

NEWS

Supply of 50KWp of PV trackers to project in the East Midlands.

Supply of PV trackers to projects in The West Midlands & Kent.

Supply of complete off grid solar system to Univ. of West of Scotland.        

Supply of 20KW of solar PV to single project in Sudan.

Supply of complete 2KW wind turbine system + 5000W inverter  in Kent

Supply & installation of complete off-grid 2KW wind turbine + diesel genset and batteries near Doncaster.

Supply & installation of PV system for battery charging in Manchester.