PowerOne Aurora Grid Tie Wind Turbine Inverters
CALL 0161 881 1383 for information or to order
G83 certification for the 3.6Kw
and 6Kw inverters ensures that these products meet the stringent United Kingdom
requirements for quality, reliability, compliance with UK
interconnection standards and, most importantly, optimum transformerless energy harvesting efficiency (in excess of 96%).
Maximum Power
Point Tracking (MPPT), enables the Aurora inverter to
use a 16-point power curve to optimize energy
harvested from wind turbines. By means of proprietary MPPT
circuitry and software, Aurora can be programmed to increase the
energy extracted from the wind power curve (50-580 volts DC) in
virtually any wind power system on the market today. .
Aurora wind inverters incorporate robust,
high-efficiency designs that include features such as the capability
to optimize the inverter’s power curve to match the specific output
characteristics of the wind turbine being used.
Aurora wind interfaces
are available to condition the output of a micro-wind generator for
use with a wind inverter; eliminating the need for any additional
rectification. The Wind
Interface Box is designed to specifically operate with the Aurora Wind
Inverter. It has been matched to complete the power conversion package
with diversion load control and wind speed feedback. In addition,
there is an integrated RS485 communication link
with optional RS232 converter
(we do not supply these but can provide details of a
suitable supplier) and
free communication software
available to
program/modify the power
curve and monitor
the unit.
You will usually need a dump load for every wind interface used. Usually the
dump load power is sized based on 1.5 times the turbine capacity. ie
for a 5kW turbine a 7500W dump load is used. However, for turbines
with greater power than the inverter rating, then the dump load is
sized based on 1.5 times the capacity of the inverter which in this
case would be 9000W.
However,
it comes down to the characteristics of
the controller and the turbine. If you can guarantee that the
turbine/controller output voltage will not exceed 600V then you will
not need a dump load. If
the characteristics of the turbine are not well documented then it is
probably a good idea to include a dump load in the system.
If, for example, the
load (grid) is removed for some reason, under no load conditions the
turbine speed and therefore output voltage will increase considerably.
If the voltage exceeds 580VDC then there is a strong possibility that
the inverter will be damaged.
A wind interface is recommended for every inverter. However, you may
find that the turbine manufacturer use their own controller and this
may negate the need for the Magnetek interface unit and dump load
2 YEAR WARRANTY.
QUOTATIONS
ARE AVAILABLE FOR AN EXTENSION TO 5 YEARS
6000W Aurora
Inverter
-
IP65 (NEMA 4) ruggedized,
completely sealed unit to stand the harshest environmental
conditions
-
High speed MPPT for real
time power tracking and improved energy harvesting
-
Compact size and high power
density: 6000W (6000W max) of output power in a box just 740mm x
325mm x 195mm
-
Front heatsink keeps the
unit cleaner and more effi cient over time
-
Transformerless operation
for highest efficiency: up to 97% (96,5% Euro; 96,5% C.E.C.)
-
Reverse polarity protection
minimizes chance of damage due to mis-wiring, only if used in
conjunction with Aurora PVI-WIND-INTERFACE BOX.
-
High overload capability:
works up to 6000W under most ambient conditions
-
True Sine Wave Output
-
Anti-islanding Protection
-
Certified grid connected
operation according to the International standards (including
G83 in the UK)
-
LCD Display on the front to
monitor the main parameters
-
Integrated RS-485 serial
communication
-
WIND INTERFACE BOX is
optional
3600w Aurora Inverter
- PMG (Permanent Magnet Generator) Power Curve implemented in high
speed MPPT
- IP65 (NEMA 4X)—The completely sealed, rugged unit can withstand
the harshest
environmental conditions
- High speed MPPT for real time power tracking and improved energy
harvesting
- Compact size and high power density: 3600W of output power in a
box just 420mm x 326mm x 141mm
(16.5in x 12.8in x 5.55in)
- Front heatsink keeps the unit cleaner and more effi cient over
time
- Transformerless operation for highest efficiency—up to 96%
- Reverse polarity protection minimizes chance of damage due to
incorrect wiring, only if used
in conjunction with Aurora PVI-WIND-INTERFACE BOX.
- High overload capability—works up to 3600W under most ambient
conditions
- True Sine Wave Output
- Anti-islanding Protection
- Certified grid connected operation according to the
international standards
- LCD on the front to monitor the main parameters and display kW
and kWh
- Wind interface box is optional
| Wind
Turbine Output /Size |
|
2Kw, 2.5Kw or 3 KW
wind turbine
COMPLETE SYSTEM PACKAGES
Wind
turbine
requiring 1 x 3600W
Aurora inverter +
6A
wind interface +
suitable dumpload.
For 1 unit of
3600W
inverter
the cost will be
£1505.00 + VAT
@ 17.5% = £1768.38
For 2-4 units
of 3600W inverter the cost will be £1465.00
+
VAT @ 17.5%
=
£1721.38
6A
wind interface
at £310
+ VAT
@ 17.5%
= £
364.25
DUMP
LOAD AS INDICATED BELOW
-----------------------
Dump Load options
For 2.0Kw use Braking
resistor 3000W, 20 Ohm = £200.00
+ VAT
@ 17.5%
= £ 235.00
For 2.5Kw use Braking
resistor 3750W, 20 Ohm = £200.00
+ VAT
@ 17.5%
= £ 235.00
For 3.0Kw use Braking
resistor 4500W, 22 Ohm = £348.94
+ VAT
@ 17.5%
= £ 410.00

Aurora Wind
inverter 3600W , IP65 rated, non isolated, 230VAC output.
PVI-3600-OUTD-UK-F-W Data Sheet
Manual Installation PVI-3600-OUTD-UK-F-W

Wind Interface 4000 (400VAC -7A-EU rectifier + over
voltage protection
interface) for Aurora Wind inverter 3600W
PVI-4000-Wind-Interface-UK Data Sheet
Manual Installation PVI-WIND
|
|
5KW or 6Kw wind turbine
COMPLETE SYSTEM PACKAGES
5Kw
or 6kW
turbine requiring 1 x 6000W Aurora inverter + 15A wind interface
Single 6000 inverter
at
£1950.00
+ VAT
@ 17.5%
= £2291.25
Single
15A wind interface at £310
+ VAT
@ 17.5%
= £
364.25
For 2-6 units
of the 6000W inverter the unit cost will be £1890.00
+ VAT
@ 17.5%
= £2220.75
DUMP
LOAD AS INDICATED BELOW
-------------------------------
Dump Load options
For 5Kw or 6 Kw use
Braking resistor 9000W, 22 Ohm = £442.55
+ VAT
@ 17.5%
= £520.00

Aurora Wind inverter
6000W , IP65 rated, non isolated, 230VAC output.
PVI-6000-OUTD-UK-W Data Sheet

Wind Interface 7200 (400VAC -15A-EU rectifier + over
voltage protection
interface) for Aurora Wind inverter 6000W
PVI-7200-Wind-Interface-UK Data Sheet
Manual
Installation PVI-WIND
|
|
10KW turbine
COMPLETE SYSTEM PACKAGES
10Kw turbine requiring 2 x 6000W Aurora inverters
+ 2 x 15A wind interfaces +
a
single
7.5
Kva isolation transformer
2 x 6000W
Aurora inverters at
£1890.00
+ VAT
@ 17.5%
= £2220.75
each =
£4441.50 total
2 x 15A wind interface at £310
+ VAT
@ 17.5%
= £
364.25
each = £
728.50
1 x
7.5
Kva isolation transformer at £663.83
+ VAT
@ 17.5% = £780.00
2 x
Dump load
9000W at £439.00
+ VAT
@ 17.5% =
£515.82 each = £ 1031.64
You
will need a dump load for every wind interface used. Usually the
dump load power is sized based on 1.5 times the turbine
capacity. ie for a 5kW turbine a 7500W dump load is used.
However, for turbines with greater power than the inverter
rating, then the dump load is sized based on 1.5 times the
capacity of the inverter which in this case would be 9000W.
NOTE:
A new 10KW
3-phase inverter in a single case is due in Summer 2010. This will
remove the need for parallel 6000W inverters and there will be
no need for an isolation transformer. The design allows for
these 10KW units to be paralleled up to 50Kw on 3 phase. 
Aurora Wind inverter 6000W , IP65 rated, non isolated, 230VAC
output
PVI-6000-OUTD-UK-W Data Sheet

Wind Interface 7200 (400VAC -15A-EU rectifier + over
voltage protection
interface) for Aurora Wind inverter 6000W
PVI-7200-Wind-Interface-UK Data Sheet
Manual
Installation PVI-WIND
|
|
20KW turbine
COMPLETE SYSTEM PACKAGES
20Kw turbine requiring 4 x 6000W Aurora inverters
+ 4 x 15A wind interfaces +
3
x
7.5 Kva isolation transformers
4
x 6000 Aurora inverters
at
£1890.00
+ VAT
@ 17.5%
= £2220.75
each = £ 8883.00
4 x 15A wind interface at £310
+ VAT
@ 17.5%
= £
364.25
each = £1457.00
3 x
7.5
Kva isolation transformer
at
£663.83
+ VAT
@ 17.5% = £780.00
each = £2340.00
3
x
Dump load
9000W at £439.00
+ VAT
@ 17.5% =
£515.82 each = £ 1547.46
You
will need a dump load for every wind interface used. Usually the
dump load power is sized based on 1.5 times the turbine
capacity. ie for a 5kW turbine a 7500W dump load is used.
However, for turbines with greater power than the inverter
rating, then the dump load is sized based on 1.5 times the
capacity of the inverter which in this case would be 9000W.
NOTE; A new 10KW
3-phase inverter in a single case is due early in 2010. This will
remove the need for 4 in parallel 6000W inverters but there may
still be a need for single isolation transformer on a 20Kw
turbine installation. For a 20KW 3-phase
system just 2 of these 10KW inverters in parallel will be
required.

Aurora Wind inverter 6000W , IP65 rated, non isolated, 230VAC
output
PVI-6000-OUTD-UK-W Data Sheet

Wind Interface 7200 (400VAC -15A-EU rectifier + over
voltage protection
interface) for Aurora Wind inverter 6000W
PVI-7200-Wind-Interface-UK Data Sheet
Manual
Installation PVI-WIND
|
|
CALL 0161 881 1383
for information or to order.
|
|